Late Catch-Up Phenomenon in BuMA Supreme vs XIENCE Stents: Study

Compuscript Ltd

https://www.scienceopen.com/hosted-document?doi=10.15212/CVIA.2024.0024

Announcing a new article publication for Cardiovascular Innovations and Applications journal. This study was aimed at comparing the "late catch-up" phenomenon between the BuMA Supreme bioresorbable polymer sirolimus-eluting stent and the XIENCE stent through serial optical coherence tomography (OCT) at within 2 months and 2 year follow-ups.

A total of 49 of 75 patients from the PIONEER-II study were enrolled in a 2 year OCT follow-up study; 44 patients with 50 lesions were included in the statistical analysis. The primary endpoints were neointimal thickness and late luminal loss (LLL) after stent implantation.

The stenosis diameter, and minimum in-stent or in-segment diameter, did not significantly differ between the BuMA Supreme and XIENCE arms at within 2 months and 2 year follow-ups. The strut neointimal coverage and thickness were greater in the BuMA group than the XIENCE group at the 1 and 2 month follow-ups (P = 0.044 and P = 0.010, respectively) but not at the 2 year OCT follow-up. Neither early luminal loss at the within 2 months follow-up (P = 0.849) nor LLL at the 2 year OCT follow-up (P = 0.613) showed differences between device arms. No significant differences in imaging and clinical endpoints were observed between device arms at follow-up.

The BuMA Supreme stent's faster re-endothelization with no "late catch-up" phenomenon has potential advantages over the XIECE stent for patients with coronary artery disease and high bleeding risk because it decreases the duration of dual antiplatelet therapy.

CVIA is available on the ScienceOpen platform and at Cardiovascular Innovations and Applications. Submissions may be made using ScholarOne Manuscripts. There are no author submission or article processing fees. Cardiovascular Innovations and Applications is indexed in the SCOPUS, EMBASE, EBSCO, ESCI, OCLC, Primo Central (Ex Libris), Sherpa Romeo, NISC (National Information Services Corporation), DOAJ, Index Copernicus, Research4Life, CNKI Scholar (Chinese National Knowledge Infrastructure) and Ulrich's web Databases.. Follow CVIA on Twitter @CVIA_Journal; or Facebook.

Qinhua Jin, Jianguo Cui and Changqian Wang et al. Comparison of the "Late Catch-Up" Phenomenon Between BuMA Supreme and XIENCE Stents Through Serial Optical Coherence Tomography at 1–2 Month and 2 Year Follow-Ups: A Multicenter Study. CVIA. 2024. Vol. 9(1). DOI: 10.15212/CVIA.2024.0024

/Public Release. This material from the originating organization/author(s) might be of the point-in-time nature, and edited for clarity, style and length. Mirage.News does not take institutional positions or sides, and all views, positions, and conclusions expressed herein are solely those of the author(s).View in full here.