"I am trained as a chemical engineer," says Angela. "However, I have worked extensively with materials research and product formulation, particularly in connection with my PhD."
The industrial PhD project is a collaboration between the Department of Biomaterials at the University of Oslo and Corticalis AS, with salary costs shared equally between Corticalis and the Research Council of Norway. Proximity to the clinics made it easy to receive feedback from dentists.
Feedback from the clinical community
"We have seen a need for new products because there is no consensus within the professional community about which cleaning method works best. We therefore wanted to investigate products that could make a difference," Angela explains.
Can you describe what you did in your doctoral thesis?
"We studied titanium surfaces, which are used in dental implants. Dental implants differ from natural teeth and require adapted cleaning. Inflammatory conditions such as peri-implant mucositis and peri-implantitis can develop around implants.
"Bacterial deposits, also known as biofilm, play a key role in the development of these diseases. It is therefore important to remove these deposits. Many strategies exist for cleaning implant surfaces, but no single solution has been shown to work best in every situation.
"We therefore focused on testing a titanium brush and different gels, both separately and in combination. We investigated how the treatments affected the protein layer on the implant surface, and whether cells were able to adhere after cleaning," says Angela.
Investigating the protein layer on the implant surface
What were the key findings of your study?
"When we began the study, we took a step back and investigated proteins from saliva. These adhere to the implant surface and form a thin layer that can affect how bacteria and the body's own cells adhere. We analysed how the cleaning methods affected this layer.
"The protein layer is called a pellicle. The experiments showed that the cleaning methods affected the amount and composition of proteins on the surface in different ways. The poloxamer gels and titanium brush investigated showed promising results for protein removal and cell adherence under the laboratory conditions used. However, the protein layer was not completely removed."
The effects on bacterial deposits are being investigated in other projects. The findings of the thesis must also be followed up through clinical studies before it can be established whether the methods provide better treatment and healing in patients.
Did you try the treatment on patients?
"No, we have not done that yet, but that is the goal. My project is aimed at the health industry, and I want it to benefit patients," says Angela.
The project also aimed to investigate how the products can be manufactured and further developed for clinical use.
"You need to conduct good research, but you also need to consider how the results can be translated into products that can be manufactured and used clinically. In short, it is about how patients can benefit from the research."
Testing in the laboratory
Can you describe the method you used?
"The experiments were carried out on titanium discs with surface structures that mimic the surfaces of dental implants. We allowed proteins from saliva to form a layer on the surfaces," Angela explains.
"We then used the gels and titanium brush to clean the surfaces and compared them with other products available on the market. We measured the amount of protein and performed proteomic analyses - that is, analyses that map which proteins are present in the surface layer.
"We also investigated how the products affected the surface chemistry, and how cells adhered after treatment with the gels, the titanium brush, and the combination of the two."
A separate part of the work concerned sterilisation, which is important in the development of products for clinical use. Sterilisation may alter the properties of a gel. The researchers therefore compared different methods and found that moist heat and electron-beam irradiation preserved key properties of the Poloxamer 407 gel studied.
Potential for clinical use
What can your research be used for?
"The goal is that, in the long term, these tools can be used in the prevention and treatment of disease around dental implants," says Angela.
"Prevention is important. We want to develop products that can help keep implants healthy, and that may also be useful once inflammation has developed."
Knowledge about the relationship between the protein layer and bacterial adherence may provide a better basis for developing such products.
"The goal is products that can contribute to effective cleaning while also preserving favourable conditions for the cells that are to contribute to healing," Angela emphasises.
The study showed that each cleaning method affected the protein layer on the implant surface in its own way. It is therefore important to understand which proteins adhere to and remain on the surface. This may influence how both cells and bacteria subsequently respond to it.
Gels with a micellar structure
The gels are based on the polymer Poloxamer 407. The researchers investigated formulations both with and without hydrogen peroxide. The aim was to combine cleaning with favourable conditions for cell adherence.
In the gel, polymer molecules can assemble into small structures called micelles. The idea is that the gel will help loosen and transport material away from the implant surface. Rinsing and suctioning the treatment gel is designed to simultaneously wash away and extract the loosened debris from the treatment area.
"That is the concept we have developed," says Angela.
"The aim was to develop something that can be used for cleaning while also taking the implant surface and the cells that come into contact with it into account," she adds.
What is the next step for the products?
The work provides a basis for further product development and testing. Before the researchers can determine if the products can benefit the patients, the laboratory results need clinical investigations.
"It has been very interesting to work with this from both a research perspective and an industrial perspective. The goal is for the research to benefit patients," Angela concludes.
References
- A Comparative Study of the Impact of Chemical Debridement Products on the Proteomic Profile of the Salivary Pellicle and Cell Adhesion on OsseoSpeed Titanium Dental Implant Surfaces
- Combined Chemical and Mechanical Debridement Enhances Salivary Protein Removal from Titanium while Maintaining Biological Properties