Intracranial aneurysms are weakened, bulging areas of cerebral arteries that can rupture, causing subarachnoid hemorrhage and, in turn, significant disability or death. While endovascular treatments have advanced significantly, wide-necked intracranial aneurysms present major challenges, as coils may move the parent artery during embolization. In such cases, stent-assisted coiling, which places a scaffold across the neck to stabilize coils, can be useful. One such device, the low-profile visualized intraluminal support (LVIS) stent, is a braided, self-expanding nitinol device with relatively high metal coverage. Beyond providing scaffolding, it may also alter blood flow inside the aneurysm and encourage thrombosis and healing. However, a thorough evaluation of its safety profile is still lacking.
Addressing this challenge, a research team led by Professor Xiang Xu from the Department of Neurosurgery at the Tangshan Gongren Hospital, China, evaluated whether LVIS stent-assisted coiling could provide effective aneurysm occlusion while producing measurable hemodynamic changes and maintaining procedural safety. The retrospective study included 61 patients with wide-necked intracranial aneurysms receiving LVIS stent-assisted coiling between January and December 2023: 35 had ruptured aneurysms and 26 had unruptured aneurysms. Researchers assessed immediate angiographic occlusion using the Raymond-Roy Occlusion Classification (RROC), functional outcomes using the modified Rankin Scale (mRS), follow-up angiography, parent artery patency, recurrence, and complications. A subset of 14 patients underwent computational fluid dynamics (CFD) analysis before treatment, after treatment, and at 6 months. This paper was published in Volume 12 of the Chinese Neurosurgical Journal on June 29, 2026.
Initial angiography showed complete occlusion (RROC class I) in 28 of 35 ruptured aneurysms (80%) and 22 of 26 unruptured aneurysms (84.6%). Angiographic follow-up was available for 27 patients (44.3%) at 6–12 months. All aneurysms initially completely occluded remained stably occluded, while some class II aneurysms improved to complete occlusion. In ruptured cases, favorable outcomes (mRS 0–1) increased from 57.1% at discharge to 77.1% at 3–6 months. Among unruptured cases, 25 of 26 patients (96.2%) had mRS 0–1 at discharge, and all surviving patients maintained favorable outcomes at follow-up.
CFD analysis showed that treatment reduced blood-flow activity within the aneurysm. In 14 patients, the amount of blood entering the aneurysm decreased after treatment, as did the proportion of the aneurysm exposed to higher flow and the average force exerted by blood on the vessel wall. These improvements remained significantly different from baseline at 6 months, with all P < 0.001.
"The sustained reduction in intra-aneurysmal flow parameters suggests that LVIS-assisted coiling can produce durable hemodynamic remodeling," Prof. Xu noted, while emphasizing that the findings are observational rather than proof of causation.
The study also highlights procedural risks. Two patients with ruptured aneurysms experienced intraprocedural thrombosis and were successfully treated without permanent neurological deficits. Incomplete stent apposition was observed in 6 of 61 patients (9.8%). One patient with an unruptured aneurysm developed delayed in-stent thrombosis and died after unsuccessful rescue treatment and secondary cerebral hemorrhage, resulting in an overall procedure-related mortality of 1.6%.
"These findings underscore the importance of stent deployment and attention to thrombotic risk," Prof. Xu said. The findings support collaboration among neurointerventional, imaging, and computational researchers to evaluate stent apposition and thrombotic risk prospectively to improve patient selection.
Overall, the findings suggest that LVIS stent-assisted coiling may combine mechanical support with flow modification for wide-necked intracranial aneurysms, while underscoring risks of stent thrombosis and incomplete apposition. Because the study was retrospective, single-center, clinically heterogeneous, and had a 44.3% angiographic follow-up rate, the authors caution against causal conclusions. Larger prospective, comparative studies will be needed to establish safety, efficacy, and the potential role of this approach across ruptured and unruptured aneurysms.