Nanoparticle MRI Probe Quantifies pH Levels

Accurately measuring tissue acidity could improve disease diagnosis and treatment monitoring. Researchers from Science Tokyo and collaborating institutions have developed a nanoparticle contrast agent that enables quantitative pH imaging using magnetic resonance imaging. The probe designed by tuning the crosslinked polymer shell distinguishes pH values from 6.0 to 7.5 independently of its concentration, offering a promising approach for investigating tumor acidity, assessing disease progression, and monitoring treatment responses.

Nanoparticle MRI Probe-Enabled Quantitative pH Imaging

A Ratiometric MRI Probe with a Tuned Crosslinked Network for Quantitative Imaging of Physiological pH

The acidity of tissues can provide important clues about a disease. Tumors and inflamed tissues often become more acidic than their surroundings because of changes in cellular metabolism. Measuring these pH variations could help researchers understand disease progression, identify abnormal tissue environments, and evaluate treatment responses. However, detecting small pH differences inside the body remains challenging because magnetic resonance imaging (MRI) signals are affected by the concentration of the imaging agent used.

MRI provides a way to visualize deep tissues without exposing the body to ionizing radiation. To visualize tissue acidity, scientists have developed pH-responsive MRI contrast agents, which alter the MRI signal in response to changes in pH. However, the signal produced by these agents also depends on how much of the agent (probe) is present in the tissue. Consequently, a stronger or weaker signal does not necessarily indicate a change in acidity, complicating accurate pH measurement.

To address this limitation, a research team led by Associate Professor Satoshi Okada and Professor Hiroyuki Nakamura of the Laboratory for Chemistry and Life Science, Institute of Science Tokyo (Science Tokyo), Japan, has developed a new nanoparticle contrast agent for quantitative pH imaging within the body using MRI. The research was conducted in collaboration with Specially Appointed Assistant Professor Ken Kato and Professor Koichi Kato of the National Institutes of Natural Sciences, Japan, and Professor Kazuya Kikuchi of the University of Osaka, Japan.

The study, published online in the journal Small on September 23, 2026, presents a strategy for improving MRI-based pH measurements by precisely tuning the structure of a pH-responsive polymer network.

The team developed a core-shell nanoparticle comprising a silica core containing gadolinium-based MRI contrast agents and an outer shell made of a pH-responsive polymer hydrogel. They modified the shell's crosslinked network using tetraethylene glycol dimethacrylate, a chemical crosslinker that helps connect polymer chains while providing flexibility to the network. Okada explains about the core-shell nanoparticle, "As the surrounding environment became more acidic, the polymer shell shrinks, changing the nanoparticle's interaction with surrounding water and its transverse relaxation behavior. Meanwhile, its longitudinal relaxation response remained largely unchanged by pH."

To quantify these changes, the researchers employed ratiometric MRI, an approach that compares two relaxation-related measurements in order to reduce the influence of contrast agent concentration. They calculated the ratio of transverse to longitudinal relaxivity (r2/r1), allowing pH to be estimated without relying solely on MRI signal intensity. The nanoparticle successfully distinguished pH values of 6.0, 6.5, 7.0, and 7.5 across contrast agent concentrations ranging from 0.50 to 1.50 wt%. The probe also distinguished between pH 6.5 and 7.5 in the presence of fetal bovine serum, a biological material used to evaluate performance under laboratory conditions that approximates the aspects of biological environments.

The study findings highlight how modifying the molecular structure of a polymer shell can improve the sensitivity and reliability of quantitative MRI. By reducing the influence of contrast agent concentration, the technique could aid in distinguishing acidity differences in tissues more accurately. Okada explains, "Our study supports the potential for new MRI-based diagnostic approaches to accurately assess cancer progression and disease status, as well as for methods to monitor treatment response."

In the future, incorporating targeting molecules to enhance probe accumulation in specific tissues could contribute to more reliable pH imaging, facilitating the investigation of disease-associated pH changes and potentially improving the assessment of cancer progression and treatment response.

Reference

Authors:
Ken Kato1,2,3, Akira Sumiyoshi4, Kyoko Katsumata5, Hiroyuki Nakamura5, Koichi Kato1,2,3,6, Kazuya Kikuchi1,2,7*, Satoshi Okada5*
Title:
A Ratiometric MRI Probe with a Tuned Crosslinked Network for Quantitative Imaging of Physiological pH
Journal:
Small
Affiliations:
1Core for Spin Life Sciences, National Institutes of Natural Sciences, Japan

2Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Japan

3Institute for Molecular Science (IMS), National Institutes of Natural Sciences, Japan

4Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology (QST), Japan

5Laboratory for Chemistry and Life Science, Institute of Science Tokyo, Japan

6Graduate School of Pharmaceutical Sciences, Nagoya City University, Japan

7Department of Applied Chemistry, The University of Osaka, Japan

/Public Release. This material from the originating organization/author(s) might be of the point-in-time nature, and edited for clarity, style and length. Mirage.News does not take institutional positions or sides, and all views, positions, and conclusions expressed herein are solely those of the author(s).View in full here.